UNIVERSAL INDOOR/OUTDOOR CABLE#

OPTIX Cable ZW-(NV)OTKtsd 1.2kN

9/125 ITU-T G.652D

FEATURES:
  • Fully dielectric construction
  • Solid LSZH outer jacket and nylon (PA) inner jacket
  • Additional water blocking construction
  • Resistance to high and low temperatures
  • Practical and thin Ripcord

CABLE CONSTRUCTION#

  1. FRP rod
  2. Optical fibres in 0.25mm coloured coating
  3. Hydrophobic jelly
  4. Loose tube
  5. Ripcords to tear the outer jacket
  6. Filler
  7. Water blocking tape / yarns
  8. Nylon (PA) inner jacket (black)
  9. LSZH outer jacket (black)

OPTIX ZW-(NV)OTKtsd cable: a light multi-tube construction, great flexibility and durability against dragging, a central strengthening element (FRP rod), gel and a water blocking construction (WB), moisture absorbing yarns (WSY) and an anti-humidity tape fully dielectric, a double shell: black LSZH (UV radation resistant) and NYLON (PA) - anti-rodent protection, temperature range between -40°C and +70°C - a ZW-(NV)OTKtsd equivalent. Maximum installation tension: 1200N.

All fibres and tubes of the cable adhere to the "EIA/TIA-598" colour coding standard. Each tube containing up to 12 fibres is filed with hydrophobic gel for anti-moisture and anti-vibration protection. The core of the cable is being protected against water penetration by moisture absorbing yarns and anti-humidity tape. The cables tubes and filler elements are twisted along a central strengthening element - the FRP rod. Two threads are molten into the coating (ripcords) and serve the purpose of easing the removal of the outer cable layer. The use of a non-flammable, non-halogen outer shell makes the cables resistant to flame spreading and the shell layer made with Nylon (PA) provides anti-rodent protection. The cables can be used both inside, as well as outside of buildings, or building constructions. The are meant for installation in closed spaces, tunnels, in tele-technical primary and secondary canalisation by pneumatic (cable blowing) and mechanical (cable pulling) means.


OPTIX Cable ZW-(NV)OTKtsd 1.2kN

Product information
Cable
version
The total
amount of
fibres [pcs]
Weight
[kg/km]
(±10%)

Cable
[mm]
(±0.5)

Tube
[mm]
(±0.15)
Supporting
element/
Peripheral
reinforcement
Reinforcing
element
[mm] (±0.1)
Coating
material
& thickness
[mm] (±0.2)
Temp.
range
instalation
Temp.
range
operating
transport
Minimum
bending
radius
1T12F 12 120 11.2 1.4/2.0 None FRP(2.0) LSZH(1.6)+PA(0.5) -15° to +60°C -40° to +70°C 20D
2T12F 24 120 11.2 1.4/2.0 None FRP(2.0) LSZH(1.6)+PA(0.5) -15° to +60°C -40° to +70°C 20D
3T12F 36 120 11.2 1.4/2.0 None FRP(2.0) LSZH(1.6)+PA(0.5) -15° to +60°C -40° to +70°C 20D
4T12F 48 120 11.2 1.4/2.0 None FRP(2.0) LSZH(1.6)+PA(0.5) -15° to +60°C -40° to +70°C 20D
6T12F 82 120 11.2 1.4/2.0 None FRP(2.0) LSZH(1.6)+PA(0.5) -15° to +60°C -40° to +70°C 20D
8T12F 96 150 12.5 1.4/2.0 None FRP(2.0) LSZH(1.6)+PA(0.5) -15° to +60°C -40° to +70°C 20D
12T12F 144 220 15.2 1.4/2.0 None FRP(2.0) LSZH(1.6)+PA(0.5) -15° to +60°C -40° to +70°C 20D
24T12F 288 280 17.5 (±1.0) 1.4/2.0 None FRP(2.0) LSZH(1.6)+PA(0.5) -15° to +60°C -40° to +70°C 20D


Mechanical parameters EN standard IEC standard 12-24F 36-48F 72F 96-288F
Tensile Strength Installation EN 187000 IEC 60794-1-2-E1 1200N 1200N 1200N 1200N
Tensile Strength Operation EN 187000 IEC 60794-1-2-E1 500N 500N 500N 500N
Crushing resistance EN 187000, m.504 IEC 60794-1-2-E3 2000N (100x100mm) for 60 sec.
Repeated bending EN 187000, m.507 IEC 60794-1-2-E6 30 cycles [(20xD), 5Kg]